http://www.madeinwst.com
Home > Products > Heat Exchanger > 100% Pressure Test Fin Copper Tube Heat Exchanger

100% Pressure Test Fin Copper Tube Heat Exchanger

    Payment Type: L/C,T/T,Paypal
    Incoterm: FOB,CFR,CIF
    Min. Order: 1 Bag/Bags
Basic Info

BrandWST

PrincipleMixing Heat Exchanger

Structure MaterialMetal Material

CoreCore Evaporative Heat Exchanger

TypeStainless Steel Heating Equipment

ApplicationHeater

StyleSteel Type

Mixing Heat Exchanger TypeCooling Tower

Recuperative Heat Exchanger TypeTube Type Heat Exchanger

Heat Transfer SurfacePlate Heat Exchanger

Additional Info

PackagingSeaworthy Packing

Productivity1000

TransportationOcean

Place of OriginWuxi City,China

Supply Ability1000

CertificateGB ASME PED

PortSHANGHAI

Payment TypeL/C,T/T,Paypal

IncotermFOB,CFR,CIF

Product Description
100% Pressure Test Fin Copper Tube Heat Exchanger , Finned Heat Exchanger is mainly used for drying air heating system is the main device in the hot air device, the radiator heat medium can be used steam or hot water, can also be used in heat transfer oil, steam pressure is generally not more than 0.8Mpa , And the temperature of the hot air is 150 ° C or lower.
1. material : copper , aluminum,galvanized plate
2. aluminum foil: hydrophilic orbare
3. fin type: louver fin or flat finor corrugated fin
4. copper pipe: diameter 7mm or7.94mm, 9mm or 9.52mm , inner grooved or smooth tube
5. pitch of fins can be adjustedbetween 1.8-5.8mm.
6. pitch of holes and pitch of rows: 25*21.65MM and 12.7*19.05MM
7. suitable for R134A, R22, R404A,R407C refrigerant and so on
8. voltage: 220V/1/50HZ and380V/3/50HZ or other type.
9. different alternative condensing fansavailable: shaded pole or outer rotor fan motor.
10.did gas examination under3.0Mpa air pressure to ensure the tightness.
12.widely used in refrigerationindustry, cold room and other cooling system.
13. we can supply products as percustomized samples or drawing.

14.producing procedure: tube bending, punchingfin, expanding, digressing, drying Welding, leakage test, bending, inspection, Packing

Fin Tube Heat Exchanger Fin Tube Heat Exchanger

Selection of Tube Spacing and Slice Distance

      Usually, the fin-tube heat exchanger spacing and height are mainly affected by the wing-to-wing ratio, fineness ratio and the tube inside and outside the media membrane heat transfer coefficient has a great relationship. If the tube inside and outside the membrane heat transfer coefficient of difference, should select the wing than the relatively large fin tubes, such as steam heating the air. When there is phase change in one side of the medium, the difference in heat transfer coefficient will be larger, such as the exchange of hot and cold air, when the hot air below the dew point, you can use finned tube heat exchanger. In the absence of phase change of air and air heat transfer, or water and water heat exchange, usually more suitable for bare pipe. Of course, you can also use low-fin tube, because at this time belongs to the weak heat transfer coefficient, to strengthen one side of which have some effect. However, the role of the wing is too large is not obvious, the best internal and external contact area of the tube at the same time to strengthen, you can use threaded pipe or groove tube.


       Fins from the main consideration is fouling, dust, easy to clean and other factors, at the same time to be strictly in line with equipment requirements such as pressure drop. Arrangement, the pipe and the distance between the tube is not easy to too large, generally> 1mm or more for the cloth can be. In the heat transfer process, the air flow through the finned tube heat exchanger, the main is the two sides of the fin surface to participate in heat transfer. The middle part of the two fin tubes has only a small amount of radiation heat transfer, the heat transfer effect is not obvious. This part because no fin, no resistance, easy to penetrate the air. During the process of air heating, the cold air without heat exchange will neutralize the heated air passing through from the middle of the fin, but reduce the effect of heat exchange. Compared with the foreign finned tube heat exchanger, The spacing is only 0.5mm larger than the outer diameter of the fin, showing the importance of the tube spacing when arranging the finned tubes.



No. of surfaceTubes Height(mm) Thickness(mm) Dia of water pipe Length(mm)
2rows 4rows 6rows 8rows
4 228 160 180 260 330 48 300-2500
6 304 160 180 260 330 48 300-2500
8 380 160 180 260 330 48 300-2500
10 456 160 180 260 330 48 300-2500
12 532 160 180 260 330 48 300-2500
14 608 160 180 260 330 60 300-2500
16 684 160 180 260 330 60 300-2500
18 760 160 180 260 330 60 300-2500
20 836 180 200 260 350 75 300-2500
22 912 180 200 260 350 75 300-2500
24 988 180 200 260 350 75 300-2500
26 1064 180 200 260 350 75 300-2500
28 1140 180 200 260 350 75 300-2500
30 1216 210 280 280 350 90 300-2500
32 1292 210 280 280 350 90 300-2500
34 1368 210 280 280 350 90 300-2500
36 1444 210 280 280 350 90 300-2500
38 1520 246 280 280 350 110 300-2500
40 1596 246 280 280 350 110 300-2500
42 1672 246 280 280 350 110 300-2500
44 1748 246 280 280 350 110 300-2500
46 1824 246 280 280 350 110 300-2500

Product Categories : Heat Exchanger

Email to this supplier
  • *Subject:
  • *Messages:
    Your message must be between 20-8000 characters
Communicate with Supplier?Supplier
VIVI Ms. VIVI
What can I do for you?
Contact Supplier